Type F Roof Deck
F Roof Deck (Intermediate Rib)
Specifications and Span Chart below
F DECK (INTERMEDIATE RIB)
STEEL ROOF DECKING DIMENSIONS & INFO
PRODUCT INFO
Industry Designations
Type F
Intermediate Rib
IR
Type F deck is the “original” term for this deck profile, though recently the Steel Deck Institute has promoted the more descriptive name, “Intermediate Rib Roof Deck”, or “Type IR”.
Finishes
Prime Painted
Galvanized
Prime painted grey over bare steel is the most economical finish available for Type F roof deck. This prime finish typically provides adequate temporary protection to the base metal during construction, and will protect the base steel indefinitely in a properly enclosed, dry interior environment.
However, if the interior environment is more aggressive, or if greater corrosion protection is required during construction, then a galvanized coating in either G60 (0.6 ounces of zinc per square foot of metal) or G90 (0.9 ounces of zinc) is usually recommended. Government projects typically require a G90 galvanized finish.
In order to help avoid field paint adhesion issues with galvanized decks, it’s recommended that a galvanized and prime painted finish be used when a galvanized deck is to be field painted.
A white primer is also available for the underside of the F deck, but the lead time may be as long as twelve weeks. As with all white-bottom roof decks, if a field coat of paint is not going to be applied, much greater care must be taken to ensure that the steel roof deck is not exposed to moisture before it is installed and covered in a dry environment. In fact, if a white bottom finish is intended to be left exposed, the best finish to use is galvanized (G30 or heavier) and painted white.
Gauges
22
20
18
Type F roof deck is most readily available with material thicknesses defined by the even gauges 16, 18, 20, and 22. These correspond to design thicknesses of 0.0598”, 0.0474”, 0.0358”, and 0.0295”, respectively. While metal F decks can be produced in any material thickness between 16 and 22, defining an “odd” or “special” gauge will make the deck much more difficult to source.
No. of Spans | Deck Type | Max Const. Span |
1 | F22
F20 F18 |
4'-3"
5'-4" 6'-3" |
2 or more | F22
F20 F18 |
4'-11"
5'-5" 6'-3" |
What is a Type F Roof Deck?
Type F roof deck is often needed for repair and re-roof projects but is rarely used for new construction projects today. While Type F decking improved the strength-to-weight ratio of Type A Narrow Rib roof deck, it is still less efficient than Type B Wide Rib roof deck. As with all steel products, the lighter the section, the more economical it will be. Since the Type F metal roof deck cannot carry as much load at longer spans as the B deck, the steel supports below the metal deck must be spaced closer together. Unlike Type B, Type F roof deck has smaller support spacing increasing the number of supports needed and higher costs for the building owner.
To help illustrate the large disparity in capacities, consider the Factory Mutual maximum deck spans. The maximum span for the 22 GA 1.5 F Deck is only 4’-11”, but the maximum span increases to 6’-0” for the 22GA 1.5 B Deck. Type A roof deck can only span 4’-10”. The Maximum Construction spans published by the Steel Deck Institute for two or more spans show a similar pattern. These maximums are 5’-3” and 6’-11” for Type F decking and Type B, respectively, but only 3’-9” for Type A deck.
When Type A and Type F metal roof decks were developed in the 1950s and 1960s, the strength of the metal deck was only one factor that the engineering community was concerned with, and it was secondary. The primary objective was to maximize the width of the top flange to provide the maximum amount of support for the roofing insulation that would be installed on top of it. Over time roofing materials improved, and steel deck manufacturers could reduce the width of the top flange, increasing the efficiency of the section from Type A to Type F deck, and finally from Type F to Type B deck. Generally, Type A decks were used in buildings constructed from the late 1940s to the late 1950s. Subsequently, the Type F deck was used from the late 1950s through the late 1960s. Type B deck is the preferred decking choice today and has dominated the market for roof decks in new construction since it was developed in the early 1970s.
Load Capacity Limitations
Type F roof deck has a lower load capacity than Type B because, at mid-span, the top flange of the metal deck is in compression. When thin metals like 22 gauge or 20 gauge (.0295” and .0358” thick, respectively) are compressed, it is much more difficult to predict how and when they will buckle when compared to thicker sections of 0.5 inches or more. However, it is easily demonstrated that bending thin metals strengthens it significantly. While the moment of inertia of the bends can be reliably calculated, the moment of inertia of the thin, flat compression flanges is more complex. The material closest to the bends will resist buckling better than the flat material further away from the bends. Since Type F has a larger top flange (4.25” for the F deck versus 3.5” for the B deck), a large part of the top flange is not considered effective in resisting the compressive forces that result from bending.
Challenges with Type F
Like a Type A deck, replacing Type F in a repair or re-roof application may present some challenges compared to replacing a Type B metal roof deck. Since the design methodology used by the SDI has changed over time and become more conservative in the case of construction clear spans, the supports may be spaced further apart than the Type F deck, which can span at the same gauge – according to current span tables. For example, a roof that was constructed in the 1960s may have supported at 6’-0” on center with 22 gauge Type F roof deck. If a new Type F deck is to be installed on this roof, it will need to be 20 gauge, since the maximum span for 22 gauge is only 5’-3” (or 4’-11” to meet FM requirements).
When using an F deck to cover skylights, note that a 20 gauge deck or heavier will probably be required since 22 gauge will only span 4’-3” (see maximum un-shored spans for one (1) span). As shown in the Maximum Construction Span table on this page, the maximum span for one span is 8 inches shorter than the maximum allowed when each deck sheet covers two or more spans.
Contact D-MAC Industries today for same-day fulfillment of metal decking and accessories!